415W
Module Power
22.30%
Module Efficiency
12Years
Product Warranty
25Years
Power Warranty
Smart Soldering
Uniform smart soldering increases the power and efficiency of the module, and improves the power load capacity.
Optimized Module Size
M10 wafer and 54 cell design, fully considering the size and weight of modules in distributed applications.
Smart Module Packaging and Logistics
Smart module packaging solutions are used to achieve high reliability, low-cost transportation and logistics.
Optimized Electrical Parameters
The working current is about 13A, which is perfectly adapted to mainstream string inverters.
Gallium-doped Technology
Gallium-doped technology overcomes LID degradation and guarantees the long-term power generation of the module.
Mechanical Parameters
Layout | 144(6×24) |
Junction box | Split junction box, IP68, 3 diodes |
Weight | 27.5kg |
Size | 2278×1134×35mm |

Packaging Information
Pallet | 20FT Container | 40ft Container | |
---|---|---|---|
Module QTY | 31 | 155 | 620 |
Pallet QTY | 1 | 20 | 40 |
Notes: Manufacturers have final rights of explaination. |
Electrical Performance Parameters (STC Test)
Module Model | LR5-72HPH-550M | LR5-72HPH-555M | LR5-72HPH-560M |
---|---|---|---|
Maximum power (Pmax/W) | 550 | 555 | 560 |
Open-circuit voltage (Voc/V) | 49.80 | 49.95 | 50.10 |
Short circuit current (Isc/A) | 13.98 | 14.04 | 14.10 |
Peak power voltage (Vmp/V) | 41.95 | 42.10 | 42.25 |
Peak power current (Imp/A) | 13.12 | 13.19 | 13.26 |
STC: Standard test conditions |
Electrical Performance Parameters (NOCT Test)
Module Model | LR5-72HPH-550M | LR5-72HPH-555M | LR5-72HPH-560M |
---|---|---|---|
Maximum power (Pmax/W) | 411.1 | 414.8 | 418.6 |
Open-circuit voltage (Voc/V) | 46.82 | 46.97 | 47.11 |
Short circuit current (Isc/A) | 11.31 | 11.35 | 11.40 |
Peak power voltage (Vmp/V) | 38.97 | 39.11 | 39.25 |
Peak power current (Imp/A) | 10.56 | 10.61 | 10.67 |
NOCT: Normal operating cell temperature |
Mechanical Load Capacity
Maximum static load on the front (such as snow and wind) | 5400Pa |
Maximum static load on the back (such as wind) | 2400Pa |
Hail test | Diameter 25 mm, impact speed 23 m/s |
STC: Standard test conditions |
Temperature Coefficient (STC test)
Temperature coefficient of short circuit current (Isc) | +0.050%/℃ |
Temperature coefficient of open circuit voltage (Voc) | -0.265%/℃ |
Temperature coefficient of peak power (Pmax) | -0.340%/℃ |
STC: Standard test conditions |